Hybrid solar inverter

HFP 10.3 kW

HFP103248

A white Shabang HFP inverter mounted in a charcoal wall recess.
HFP series shown. Enclosure dimensions vary by model.

Each of the two MPPT inputs accepts up to 6 kW, allowing two solar arrays to operate independently. The inverter delivers 10.3 kW of AC power on a 48 V battery system.

Battery system
48 V
Maximum PV input
12 kW
MPPT trackers
2
Maximum total charging current
180 A

Operating features.

Battery-free operation
Operates without a battery or grid when solar power is sufficient for the connected load.
Battery compatibility
Supports lead-acid batteries and compatible lithium batteries with BMS communication.
Display and controls
LCD and LED display with configurable output and charging priorities. RS485 communication is included.
Optional remote monitoring
Wi-Fi or GPRS monitoring is optional and depends on the ordered configuration.

HFP103248

Technical specifications

PV and AC charging share the total charging-current limit. Optional features depend on the ordered configuration. Specifications may change without prior notice.

Download datasheet
AC output
Rated output power
10,300 W
Rated output voltage
230 VAC; 220 / 240 VAC selectable
Rated output frequency
50 / 60 Hz
Output waveform
Pure sine wave
Off-grid output voltage accuracy
±2%
Off-grid output frequency accuracy
±1%
On-grid power factor
>0.98 at rated power
Solar input
Maximum PV input power
12,000 W (6,000 W × 2)
MPPT tracking voltage range
80–450 VDC
Maximum PV open-circuit voltage
500 VDC at lowest temperature
Maximum PV input current
22 A × 2
MPPT tracking / input channels
2
Battery & charging
Battery compatibility
Lead-acid / compatible lithium batteries
Rated battery voltage
48 VDC
Default battery voltage range
42–60 VDC
Maximum PV charging current
180 A
Maximum AC charging current
120 A
Maximum total charging current
180 A
Charging and discharging settings
Configurable
AC input
Rated AC input voltage
230 VAC; 220 / 240 VAC selectable
Rated input frequency
50 / 60 Hz
Off-grid AC input voltage range
165–280 VAC / 120–280 VAC
Off-grid input frequency range
45–55 Hz (50 Hz) / 55–65 Hz (60 Hz)
Hybrid / on-grid voltage range
187–264 VAC
Hybrid / on-grid frequency range
47–52 Hz (50 Hz) / 57–62 Hz (60 Hz)
Performance & communication
Peak conversion efficiency, battery discharge
94%
MPPT tracking efficiency
≥99.9%
Typical no-load loss, battery discharge
1% of rated power
Typical transfer time
10 ms
Display
LCD + LED
Cooling
Intelligently controlled fan
Communication
RS485
Remote monitoring
Mobile app; Wi-Fi / GPRS optional
Protection
Default battery low-voltage alarm
44 VDC
Default battery low-voltage protection
42 VDC
Anti-islanding protection
≤2 s
Overload / output short-circuit protection
Automatic in battery mode; AC circuit protection
Overtemperature protection
Shutdown above 90°C
Installation & environment
Protection degree
IP20
Installation
Wall-mounted
Operating temperature
−10°C / +50°C
Storage temperature
−15°C / +60°C
Noise
≤55 dB
Altitude
2,000 m; derating above 2,000 m
Humidity
0–95%, non-condensing
Dimensions & weight
Unit dimensions (L × W × H)
535 × 462 × 117 mm
Package dimensions (L × W × H)
630 × 557 × 212 mm
Net weight
14.7 kg

CE · LVD

Safety certificates

Original certificates and test reports are provided for the HFP models listed. Refer to each document for issuer and model details.

SZNTC2408210SV00

Shenzhen Nore Testing Center Co., Ltd.

Standards
EN 62109-1:2010 · EN 62109-2:2011
Issued
Models listed in this document
HFP103248 · HFP83248

Technical documents